INSTRUCTIONS ON INSTALLING A SCANNER ON A PCI PARALLEL PORT Question: I have a Lava Parallel PCI card and I am trying to attach a scanner. What should I do to get it to install? Answer: Some scanners cannot install on the initial address range that the Lava parallel port is assigned to. When the scanner is attached to the Lava PCI parallel port it can install on one of the following three IO address ranges. 0378 - 037F 0278 - 027F 0288 - 028F It is necessary to verify which IO address your on-board parallel port is assigned to before changing the Lava PCI parallel port's address range. If the on-board parallel port is set to 0378 - 037F (default setting) then the Lava parallel port must be set to 0278 - 027F or 0288 - 028F. Do this with the following method: 1) Go to Start|Settings|Control Panel|System. Click the Device Manager tab. 2) Enter the properties then resources for the Lava PCI parallel port. 3) Uncheck Use Automatic Settings and double-click the word Output in the Input/Output Range and enter the address range you have chosen for the Lava Parallel PCI. In some cases Windows will give an error message to the effect that "Windows cannot modify this resource." If you are unable to access the settings for changing system resources, reboot the system in Safe Mode to make changes to resource settings. (To enter Safe Mode, press the F8 key while the system is rebooting). 4) Click Ok and then Ok again and reboot Windows. 5) Run the setup program provided by the scanner and it should find the scanner. 6) Some scanners have the ability to configure settings in Device Manager in SCSIControllers. Try one of the following settings in the Device Manager's Settings tab: /w95 or /w95 /di or /di IN WINDOWS 98 ONLY -- If these settings are not added the system may not boot normally! (currently only for Microtek Scanners; however, may work with others) /n /v /s/f=30 KNOWN ISSUES WITH LAVA PCI PARALLEL PORTS AND THE 278 ADDRESS RANGE Sometimes when switching a Lava PCI parallel port to 0278 - 027F it conflicts with some scanners. If this occurs try using the 0288 - 028F address range. If that does not work then it is necessary to reinstall the on-board parallel port as the 3BC port and to modify the Lava PCI parallel port as the 0378 - 037F port. Do this as follows: a) Go to the Lava Parallel PCI in Device Manager. Go to Resources and recheck Automatic Settings. Click OK and then click refresh. b) Remove the Lava Parallel PCI from Device Manager and LPT1. c) Shut Down your computer and reboot. d) As you are booting up enter your CMOS setup by hitting F1 or DEL or the appropriate key for your motherboard. e) Enter the menu for configuring your on-board parallel port to the 3BC address. f) Save this new setting and exit. NOTE: Consult your motherboard manual for steps d), e), and f). g) Boot into Windows and let the ports reinstall. h) Reconfigure the Lava PCI parallel port to 0378-037F by going to the Resources tab. Uncheck Use Automatic Settings and then double-click Input/Output Range.